Concrete Technology and Design of Concrete Structures In a spherical dome subjected to concentrated load at crown or uniformly distributed load, the meridional force is always compressive zero tensile or compressive tensile compressive zero tensile or compressive tensile ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Due to circumferential action of the spiral in a spirally reinforced column Capacity of column is decreased but ductility of column increases Capacity of column is decreased Ductility of column reduces Both the capacity of column and ductility of column increase Capacity of column is decreased but ductility of column increases Capacity of column is decreased Ductility of column reduces Both the capacity of column and ductility of column increase ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures If the foundations of all the columns of a structure are designed on the total live and dead load basis, then the settlement of interior columns will be more than exterior columns the settlement of exterior columns will be more than interior columns there will be no settlement of columns there will be no differential settlement the settlement of interior columns will be more than exterior columns the settlement of exterior columns will be more than interior columns there will be no settlement of columns there will be no differential settlement ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Sinking of an intermediate support of a continuous beami) reduces the negative moment at supportii) increases the negative moment at supportiii) reduces the positive moment at center of spaniv) increases the positive moment at center of spanThe correct answer is (i) and (iv) (ii) and (iii) (ii) and (iv) (i) and (iii) (i) and (iv) (ii) and (iii) (ii) and (iv) (i) and (iii) ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures For concreting of heavily reinforced sections without vibration, the workability of concrete expressed as compacting factor should be 0.75 - 0.80 0.85 - 0.92 Above 0.92 0.75 - 0.80 0.75 - 0.80 0.85 - 0.92 Above 0.92 0.75 - 0.80 ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures As compared to ordinary portland cement, high alumina cement has lower initial and final setting times higher initial and final setting times higher initial setting time but lower final setting time lower initial setting time but higher final setting time lower initial and final setting times higher initial and final setting times higher initial setting time but lower final setting time lower initial setting time but higher final setting time ANSWER DOWNLOAD EXAMIANS APP