• HOME
  • QUIZ
  • CONTACT US
EXAMIANS
  • COMPUTER
  • CURRENT AFFAIRS
  • ENGINEERING
    • Chemical Engineering
    • Civil Engineering
    • Computer Engineering
    • Electrical Engineering
    • Mechanical Engineering
  • ENGLISH GRAMMAR
  • GK
  • GUJARATI MCQ

Concrete Technology and Design of Concrete Structures

Concrete Technology and Design of Concrete Structures
Which of the following losses of prestress occurs only in pretensioning and not in post-tensioning ?

loss due to friction
creep of concrete
shrinkage of concrete
elastic shortening of concrete

ANSWER DOWNLOAD EXAMIANS APP

Concrete Technology and Design of Concrete Structures
If a beam fails in bond, then its bond strength can be increased most economi-cally by

using thinner bars but more in number
using thicker bars but less in number
providing vertical stirrups
increasing the depth of beam

ANSWER DOWNLOAD EXAMIANS APP

Concrete Technology and Design of Concrete Structures
In the design of a front counterfort in a counterfort retaining wall, the main reinforcement is provided oni) bottom face near counterfortii) top face near counterfortiii) bottom face near centre of spaniv) top face near centre of span The correct answer is

only (ii)
only (i)
both (i) and (iv)
both (ii) and (iii)

ANSWER DOWNLOAD EXAMIANS APP

Concrete Technology and Design of Concrete Structures
Sinking of an intermediate support of a continuous beam i) reduces the negative moment at support ii) increases the negative moment at support iii) reduces the positive moment at center of span iv) increases the positive moment at center of span The correct answer is

(ii) and (iii)
(i) and (iv)
(i) and (iii)
(ii) and (iv)

ANSWER DOWNLOAD EXAMIANS APP

Concrete Technology and Design of Concrete Structures
While designing the pile as a column, the end conditions are nearly

both ends hinged
one end fixed and other end free
one end fixed and other end hinged
both ends fixed

ANSWER DOWNLOAD EXAMIANS APP

Concrete Technology and Design of Concrete Structures
Cube strength of controlled concrete to be used for pretensioned and post-tensioned work respectively should not be less than

53 MPa and 42 MPa
35 MPa and 42 MPa
42 MPa and 35 MPa
42 MPa and 53 MPa

ANSWER DOWNLOAD EXAMIANS APP
MORE MCQ ON Concrete Technology and Design of Concrete Structures

DOWNLOAD APP

  • APPLE
    from app store
  • ANDROID
    from play store

SEARCH

LOGIN HERE


  • GOOGLE

FIND US

  • 1.70K
    FOLLOW US
  • EXAMIANSSTUDY FOR YOUR DREAMS.
  • SUPPORT :SUPPORT EMAIL ACCOUNT : examians@yahoo.com

OTHER WEBSITES

  • GUJARATI MCQ
  • ACCOUNTIANS

QUICK LINKS

  • HOME
  • QUIZ
  • PRIVACY POLICY
  • DISCLAIMER
  • TERMS & CONDITIONS
  • CONTACT US
↑