Process Equipment and Plant Design In a multiple effect evaporator system having 'n' effects, the amount of water evaporated per unit surface area in approximately equal to __________ times that in a single effect. (1/n)th 1.5 nth 0.5 nth nth (1/n)th 1.5 nth 0.5 nth nth ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement about the design of seive plate column and the bubble cap column. Weir height in case of a bubble cap plate ranges from 50 to 150 mm and is higher than the seive plate Weir length for a bubble cap plate is the same as that for the seive plate Weir height for a bubble cap plate column is the same as that for a seive plate column The downcomer design and the residence time in the downcomer is almost same for seive plate and bubble cap columns Weir height in case of a bubble cap plate ranges from 50 to 150 mm and is higher than the seive plate Weir length for a bubble cap plate is the same as that for the seive plate Weir height for a bubble cap plate column is the same as that for a seive plate column The downcomer design and the residence time in the downcomer is almost same for seive plate and bubble cap columns ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design A perforated plate has holes of diameter dh arranged in a pitch ph. Each hole has a tube of I.D. dt passing through it. The ligament efficiency is given by (ph - dh)/dh (ph - dt)/ph (ph - dh)/ph (ph - dh . dt/2)/ph (ph - dh)/dh (ph - dt)/ph (ph - dh)/ph (ph - dh . dt/2)/ph ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design __________ shapedroof is the most commonly used roof for cylinderical storage tanks. Dome Flat Conical Umbrella Dome Flat Conical Umbrella ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Floating head heat exchangers are used for the Heat transfer between corrosive fluids Cases where temperature difference between the shell and the tubes is more (>50°C) Counter-current heat transfer systems Co-current heat transfer systems Heat transfer between corrosive fluids Cases where temperature difference between the shell and the tubes is more (>50°C) Counter-current heat transfer systems Co-current heat transfer systems ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design In actual operation of distillation column, the vapour is not distributed uniformly among the bubble caps, primarily because of the Lower skirt clearance Small downcomer liquid seal Lower static submergence Liquid gradient on the tray Lower skirt clearance Small downcomer liquid seal Lower static submergence Liquid gradient on the tray ANSWER DOWNLOAD EXAMIANS APP