Process Equipment and Plant Design In case of bubble cap distillation column of diameter greater than 1.2 metres, the cap diameter is roughly about __________ cms. 30 10 35 20 30 10 35 20 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Holes of a sieve tray are arranged in triangular pitch of __________ times the hole diameter. 1.5 to 2 2.5 to 5 5 to 10 10 to 15 1.5 to 2 2.5 to 5 5 to 10 10 to 15 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Optimum economic pipe diameter for fluid flow is determined by the Viscosity of the fluid Total cost considerations (pumping cost plus fixed cost of the pipe) None of these Density of the fluid Viscosity of the fluid Total cost considerations (pumping cost plus fixed cost of the pipe) None of these Density of the fluid ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design A cylindrical storage tank can have a self supported conical roof, If its diameter is more than 50 meters Irrespective of its diameter If the thickness of the roof is more than that of the cylindrical shell If its diameter is less than 15-20metres If its diameter is more than 50 meters Irrespective of its diameter If the thickness of the roof is more than that of the cylindrical shell If its diameter is less than 15-20metres ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Floating head heat exchangers are used for the Cases where temperature difference between the shell and the tubes is more (>50°C) Counter-current heat transfer systems Heat transfer between corrosive fluids Co-current heat transfer systems Cases where temperature difference between the shell and the tubes is more (>50°C) Counter-current heat transfer systems Heat transfer between corrosive fluids Co-current heat transfer systems ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement about routing of fluids in a shell and tube heat exchanger. Higher pressure fluid stream should be routed through the shell side The viscous fluid should be routed through the shell side Lower flow rate fluid should be routed through the shell side The corrosive and fouling fluid should be preferably routed through the tubes Higher pressure fluid stream should be routed through the shell side The viscous fluid should be routed through the shell side Lower flow rate fluid should be routed through the shell side The corrosive and fouling fluid should be preferably routed through the tubes ANSWER DOWNLOAD EXAMIANS APP