Power Systems Which of following statement are false In a nuclear reactor, multiplication factor is kept almost equal to one. Nuclear power plants are used as peak load plants only. A thermal reactor needs a moderator material. In nuclear power plants, chain reaction is controlled by cadmium rods. In a nuclear reactor, multiplication factor is kept almost equal to one. Nuclear power plants are used as peak load plants only. A thermal reactor needs a moderator material. In nuclear power plants, chain reaction is controlled by cadmium rods. ANSWER DOWNLOAD EXAMIANS APP
Power Systems Gas coolled reactor use CO2. or helium as coolant and graphite the moderator. use heavy water as coolant as well as moderator. use coolant at pressure of 14-28 Kg/cm2 and at temperature of 700°-800° c. both B and C. use CO2. or helium as coolant and graphite the moderator. use heavy water as coolant as well as moderator. use coolant at pressure of 14-28 Kg/cm2 and at temperature of 700°-800° c. both B and C. ANSWER DOWNLOAD EXAMIANS APP
Power Systems A lossless power system has to serve a load of 250 MW. There are two generators(G1 and G2) in the system with cost curves C1 and C2 respectively defined as follows: C1 = PG1+0.055P²G1 C2 = 3 PG2 + 0.03 P²G2 Where PG1 and PG2 are the MW injections from generators G1 and G2 respectively. Thus, the minimum cost dispatch will be PG1 = 150 MW and PG2 = 100 MW PG1 = 250 MW and PG2 = 0 MW PG1 = 100 MW and PG2 = 150 MW PG1 = 0 MW and PG2 = 250 MW PG1 = 150 MW and PG2 = 100 MW PG1 = 250 MW and PG2 = 0 MW PG1 = 100 MW and PG2 = 150 MW PG1 = 0 MW and PG2 = 250 MW ANSWER DOWNLOAD EXAMIANS APP
Power Systems What is the total installed power capacity (MW) in West Bengal as published by ministry of power in 2011? 6114.05. 15515.22. 8113.27. 10000.32. 6114.05. 15515.22. 8113.27. 10000.32. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The neutral of 10 MVA, 11 kV alternator is earthed through a resistance of 5 ohms. The fault ready is set to operate at 0.75 A. The current transformers have a ratio of 1000/5. What is the percentage of the alternator winding is protected? 85% 88.2% 11.8% 15% 85% 88.2% 11.8% 15% ANSWER DOWNLOAD EXAMIANS APP
Power Systems An isolated synchronous generator with transient reactance equal to 0.1 pu on a 100 MVA base is connected to the high voltage bus through a step up transformer of reactance 0.1 pu on a 100 MVA base. The fault level at the bus is 200 MVA 500 MVA 400 MVA 100 MVA 200 MVA 500 MVA 400 MVA 100 MVA ANSWER DOWNLOAD EXAMIANS APP