Process Equipment and Plant Design Typical static submergence for bubble cap plate column operating at atmospheric pressure may be around 5" 2.5" 0.5" 50% of the plate spacing 5" 2.5" 0.5" 50% of the plate spacing ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The minimum shell thickness for tank ≤ 15 metres diameter is limited to __________ mm, for reasons of elastic stability. 15 10 2 5 15 10 2 5 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Steam side heat transfer co-efficient for design consideration under ordinary condition can be assumed to be about __________ kcal/hr.m².°C. 2500 15000 1250 7500 2500 15000 1250 7500 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design For annular flow of a fluid, the ratio of the equivalent diameter for pressure drop calculation to the equivalent diameter for heat transfer calculation is (d1 + d2)/d2 D2/(d1 + d2) D1/(d1 + d2) (d1 + d2)/d1 (d1 + d2)/d2 D2/(d1 + d2) D1/(d1 + d2) (d1 + d2)/d1 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The ratio of tube length to shell diameter in case of liquid shell and tube heat exchanger ranges from 2 to 3 4 to 8 6 to 12 3 to 5 2 to 3 4 to 8 6 to 12 3 to 5 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design In the design of a shell and tube heat exchanger, the corrosion allowance Need not be provided for non-pressure parts like tie rods, spacers, baffles, supports etc All of these For internal cover and tube sheet is provided on both the sides For carbon steel and cast iron pressure parts is 1.5 mm (except for tubes) and for severe conditions it is 3 mm Need not be provided for non-pressure parts like tie rods, spacers, baffles, supports etc All of these For internal cover and tube sheet is provided on both the sides For carbon steel and cast iron pressure parts is 1.5 mm (except for tubes) and for severe conditions it is 3 mm ANSWER DOWNLOAD EXAMIANS APP