Building Construction The vertical posts placed at the top and bottom ends of a flight supporting the hand rail are known as Balustrades Balusters Newel posts Railings Balustrades Balusters Newel posts Railings ANSWER DOWNLOAD EXAMIANS APP
Building Construction A covering of concrete placed on the exposed top of an external wall, is known as Cornice Coping Frieze Lintel Cornice Coping Frieze Lintel ANSWER DOWNLOAD EXAMIANS APP
Building Construction For constructing a terrazzo floor, Pick up the incorrect statement from the following: A 32 mm thick layer of cement concrete (1 : 2 : 4) is laid on the base course and the surface is made smooth by trowelling After final grinding is over, oxalic acid mixed with water is spread over and rubbed hard with soft material A base course is prepared as in cement concrete flooring Glass strips are driven into the layer according to the pattern required A 32 mm thick layer of cement concrete (1 : 2 : 4) is laid on the base course and the surface is made smooth by trowelling After final grinding is over, oxalic acid mixed with water is spread over and rubbed hard with soft material A base course is prepared as in cement concrete flooring Glass strips are driven into the layer according to the pattern required ANSWER DOWNLOAD EXAMIANS APP
Building Construction The nominal thickness of one brick wall in mm, is 190 mm 200 mm 150 mm 90 mm 190 mm 200 mm 150 mm 90 mm ANSWER DOWNLOAD EXAMIANS APP
Building Construction The ceiling height of a building is Between ceiling and ground level Between ceiling and floor level Upto roof above ground level Upto ceiling from the ground level Between ceiling and ground level Between ceiling and floor level Upto roof above ground level Upto ceiling from the ground level ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m All listed here Distance of C.G. of the loads from the smaller column = 3.00 m Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m All listed here Distance of C.G. of the loads from the smaller column = 3.00 m ANSWER DOWNLOAD EXAMIANS APP