Process Equipment and Plant Design The minimum tray spacing in distillation column of diameter less than 3 ft is normally __________ inches. 34 18 24 6 34 18 24 6 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The ratio of the largest load in a test to the original cross-sectional area of the test specimen is called the __________ stress. Breaking Yield point Ultimate None of these Breaking Yield point Ultimate None of these ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement about routing of fluids in a shell and tube heat exchanger. The corrosive and fouling fluid should be preferably routed through the tubes Higher pressure fluid stream should be routed through the shell side The viscous fluid should be routed through the shell side Lower flow rate fluid should be routed through the shell side The corrosive and fouling fluid should be preferably routed through the tubes Higher pressure fluid stream should be routed through the shell side The viscous fluid should be routed through the shell side Lower flow rate fluid should be routed through the shell side ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design In hydrostatic testing of welded pipe (for leakage, strength etc.) the ratio of minimum hydrostatic test pressure to internal design pressure is around 1.5 2.5 3.5 0.5 1.5 2.5 3.5 0.5 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Practical dividing line between a ductile and brittle materials is suggested, when the ultimate elongation is about 5%. Generally, larger the knuckle radius, stronger is the corner torus section of a head. The knuckle radius provided should be less than __________ of the head. Either A or B, whichever is smaller Either A or B, whichever is larger 3 times the thickness 6% of I.D. Either A or B, whichever is smaller Either A or B, whichever is larger 3 times the thickness 6% of I.D. ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design High pressure fluid in a shell and tube heat exchanger should preferably be routed through the Shell side, if the flow is counter-current and tube side if the flow is co-current Shell side for smaller total pressure drop Tubes to avoid the expansion of high pressure shell construction Shell side for large overall heat transfer co-efficient Shell side, if the flow is counter-current and tube side if the flow is co-current Shell side for smaller total pressure drop Tubes to avoid the expansion of high pressure shell construction Shell side for large overall heat transfer co-efficient ANSWER DOWNLOAD EXAMIANS APP