Building Construction The dimensions of a half queen closer, are 9 cm × 9 cm × 9 cm 9 cm × 9 cm × 4.5 cm 1.8 cm × 4.5 cm × 9 cm 9 cm × 4.5 cm × 9 cm 9 cm × 9 cm × 9 cm 9 cm × 9 cm × 4.5 cm 1.8 cm × 4.5 cm × 9 cm 9 cm × 4.5 cm × 9 cm ANSWER DOWNLOAD EXAMIANS APP
Building Construction The function of king post in a king post roof truss is To receive the ends of principal rafter To prevent the tie beam from sagging at its centre To prevent the walls from spreading outward To support the frame work of the roof To receive the ends of principal rafter To prevent the tie beam from sagging at its centre To prevent the walls from spreading outward To support the frame work of the roof ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: The length of the foundation slab = 7.00 m Area of footing slab = 11.00 m2 All listed here Distance of C.G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m Area of footing slab = 11.00 m2 All listed here Distance of C.G. of the loads from the smaller column = 3.00 m ANSWER DOWNLOAD EXAMIANS APP
Building Construction Pick up the correct specification of one-room quarters generally adopted from the following: The size of room is either 3.5 m × 3 m or 4.2 m × 2.5 m The front verandah is kept 2 m wide Six quarters in a row All listed here The size of room is either 3.5 m × 3 m or 4.2 m × 2.5 m The front verandah is kept 2 m wide Six quarters in a row All listed here ANSWER DOWNLOAD EXAMIANS APP
Building Construction Pick up the correct statements from the following: Cracks appear on the plastered surface in the form of hair cracks Excessive thermal variations in the backing or plaster causes the plaster to fall In brick work, the efflorescence is removed by applying a solution of zinc sulphate and water All listed here Cracks appear on the plastered surface in the form of hair cracks Excessive thermal variations in the backing or plaster causes the plaster to fall In brick work, the efflorescence is removed by applying a solution of zinc sulphate and water All listed here ANSWER DOWNLOAD EXAMIANS APP
Building Construction The maximum number of steps in a flight should generally be restricted to 10 12 No limit 15 10 12 No limit 15 ANSWER DOWNLOAD EXAMIANS APP