DGVCL Exam Paper (11-12-2011) The best location of the power factor correction equipment to be installed in the transmission line is at The sending end Middle of the line Any place The receiving end The sending end Middle of the line Any place The receiving end ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Buchholz relay causes Tripping for both major and minor faults Tripping for minor faults and alarm for major faults Tripping for major faults and alarm for minor faults Alarm for both major and minor faults Tripping for both major and minor faults Tripping for minor faults and alarm for major faults Tripping for major faults and alarm for minor faults Alarm for both major and minor faults ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) The picture on the monitor of a computer is made up of tiny coloured dots called Icons Spots Points Pixels Icons Spots Points Pixels ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) If the percentage reactance of the system upto the point of fault is 20% and the base kVA is 10,000 the short ciruit kVA is 60 MVA 10 MVA 50 MVA 20 MVA 60 MVA 10 MVA 50 MVA 20 MVA ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Short circuit kVA = Base kVA/%X
DGVCL Exam Paper (11-12-2011) A 3 phase, 6 pole induction motor operates on 440 V, 50 Hz, supply. If the actual speed of the motor is 960 rpm the slip will be 4 % 6 % 5 % 0.4 % 4 % 6 % 5 % 0.4 % ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Ns = 120f/PSlip=(Ns-Nr)/NsNs = 1000 and Nr = 960 from equation of slip, S = (1000-960)/1000S = 0.04 or 4%
DGVCL Exam Paper (11-12-2011) The transient stability of a power system can be improved by Phase shifting transformer Excitation control Increasing the turbine valve opening Single pole switching of circuit breakers Phase shifting transformer Excitation control Increasing the turbine valve opening Single pole switching of circuit breakers ANSWER DOWNLOAD EXAMIANS APP