DGVCL Exam Paper (11-12-2011) A 3 phase, 6 pole induction motor operates on 440 V, 50 Hz, supply. If the actual speed of the motor is 960 rpm the slip will be 0.4 % 5 % 6 % 4 % 0.4 % 5 % 6 % 4 % ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Ns = 120f/PSlip=(Ns-Nr)/NsNs = 1000 and Nr = 960 from equation of slip, S = (1000-960)/1000S = 0.04 or 4%
DGVCL Exam Paper (11-12-2011) Bulk power transmission over long HVDC lines are preferred on account of No harmonic problems Simple protection Minimum line power losses Low cost of HVDC terminals No harmonic problems Simple protection Minimum line power losses Low cost of HVDC terminals ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) A fuse wire should have Low specific resistance and low melting point High specific resistance and high melting point Low specific resistance and high melting point High specific resistance and low melting point Low specific resistance and low melting point High specific resistance and high melting point Low specific resistance and high melting point High specific resistance and low melting point ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) A Mho relay is a Directional restrained over current relay Directional restrained over voltage relay Voltage restrained directional relay Voltage controlled over current relay Directional restrained over current relay Directional restrained over voltage relay Voltage restrained directional relay Voltage controlled over current relay ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) An IDMT relay provides A definite time cuttent characteristic An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current An inverse time current characteristic A definite time cuttent characteristic An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current An inverse time current characteristic ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Which type of back up protection is widely used for the protection of transmission lines? Remote backup Relay backup Breaker backup Control backup Remote backup Relay backup Breaker backup Control backup ANSWER DOWNLOAD EXAMIANS APP