DGVCL Exam Paper (11-12-2011) The form factor in AC means the ration of R.M.S. value to average value Peak value to r.m.s value R.M.S. value to peak value Peak value to average value R.M.S. value to average value Peak value to r.m.s value R.M.S. value to peak value Peak value to average value ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Which of the following correctly represents the sequence of operations of isolator, circiut breaker and earthing switch while opening a circuit? Open circuit breaker-open isolator-close earthing switch Close earthing switch - open ciruit- breaker-open islotor Close circuit breaker-close isolator - open earthing switch Open isolator close circuit breaker-open earthing switch Open circuit breaker-open isolator-close earthing switch Close earthing switch - open ciruit- breaker-open islotor Close circuit breaker-close isolator - open earthing switch Open isolator close circuit breaker-open earthing switch ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Rated making capacity of a ciruit breaker is equal to 2.55 X rated symmetrical breaking capacity √2 X rated symmetrical breaking capacity Rated symmetrical breaking capacity 1.11 X rated symmetrical breaking capacity 2.55 X rated symmetrical breaking capacity √2 X rated symmetrical breaking capacity Rated symmetrical breaking capacity 1.11 X rated symmetrical breaking capacity ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) The positive and negative sequence impedance of a transmission line are Different Equal Infinite Zero Different Equal Infinite Zero ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) An IDMT relay provides An inverse time current characteristic An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current A definite time cuttent characteristic A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current An inverse time current characteristic An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current A definite time cuttent characteristic A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) If the percentage reactance of the system upto the point of fault is 20% and the base kVA is 10,000 the short ciruit kVA is 60 MVA 20 MVA 50 MVA 10 MVA 60 MVA 20 MVA 50 MVA 10 MVA ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Short circuit kVA = Base kVA/%X