Process Equipment and Plant Design __________ shaped roof is most commonly used for cylindrical tanks. Umbrella Flat Cone Dome Umbrella Flat Cone Dome ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Welded joint efficiency in the design of chemical process equipment is taken as 0.95 0.85 0.55 0.75 0.95 0.85 0.55 0.75 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement pertaining to a shell and tube heat exchanger. The maximum unsupported tube span is generally about 75 times tube diameter, but is reduced to about 60 times for aluminium, copper & alloys of these Disk and doughnut baffle is the most commonly used baffle The minimum value of baffle spacing is 50 mm The maximum value of baffle spacing is equal to the I.D. of the shell The maximum unsupported tube span is generally about 75 times tube diameter, but is reduced to about 60 times for aluminium, copper & alloys of these Disk and doughnut baffle is the most commonly used baffle The minimum value of baffle spacing is 50 mm The maximum value of baffle spacing is equal to the I.D. of the shell ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design A certain pressure vessel manufacturer avoids doing reinforcements calculations for openings by always providing a reinforcing pad extending upto double the diameter of the opening and of the same material and thickness as that of the shell wall. If area compensation is accepted as a code guideline, his approach leads to safe design Only if the opening is on a horizontal cylinderical vessel Only if the opening is on spherical vessel Irrespective of the shape of the vessel Only if the opening is on a vertical cylinderical vessel Only if the opening is on a horizontal cylinderical vessel Only if the opening is on spherical vessel Irrespective of the shape of the vessel Only if the opening is on a vertical cylinderical vessel ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design __________ is the determining factor for the number of bubble caps to be used per tray. Tray diameter Liquid load Vapor load Permissible slot velocity Tray diameter Liquid load Vapor load Permissible slot velocity ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design In a double pipe concentric heat exchanger, the equivalent diameter of annulus for heat transfer would be (where, D₁ and D₂ are I.D. of inner and outer pipes) None of these (D₂² - D₁²)/D₁² D₂ - D₁ (D₂² - D₁²)/D₂² None of these (D₂² - D₁²)/D₁² D₂ - D₁ (D₂² - D₁²)/D₂² ANSWER DOWNLOAD EXAMIANS APP