Process Equipment and Plant Design Maximum plate efficiency is achieved in case of __________ flow. Cross Split Cascade Reverse Cross Split Cascade Reverse ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Multiple blade paddle agitator is used for mixing high viscosity liquids/paste in which the paddle diameter is commonly 0.8 times the tank diameter. However, the width of the blade is in the range of __________ times the paddle diameter. 0.1 to 0.25 0.65 to 0.80 0.3 to 0.5 0.5 to 0.6 0.1 to 0.25 0.65 to 0.80 0.3 to 0.5 0.5 to 0.6 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Steam side heat transfer co-efficient for design consideration under ordinary condition can be assumed to be about __________ kcal/hr.m².°C. 2500 1250 7500 15000 2500 1250 7500 15000 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design A certain pressure vessel manufacturer avoids doing reinforcements calculations for openings by always providing a reinforcing pad extending upto double the diameter of the opening and of the same material and thickness as that of the shell wall. If area compensation is accepted as a code guideline, his approach leads to safe design Only if the opening is on spherical vessel Only if the opening is on a vertical cylinderical vessel Irrespective of the shape of the vessel Only if the opening is on a horizontal cylinderical vessel Only if the opening is on spherical vessel Only if the opening is on a vertical cylinderical vessel Irrespective of the shape of the vessel Only if the opening is on a horizontal cylinderical vessel ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The distance between the top of the slots and the liquid surface when the static liquid is just ready to flow over the overflow weir is called None of these Downcomer liquid seal Static submergence Skirt clearance None of these Downcomer liquid seal Static submergence Skirt clearance ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement about routing of fluids in a shell and tube heat exchanger. The corrosive and fouling fluid should be preferably routed through the tubes Lower flow rate fluid should be routed through the shell side The viscous fluid should be routed through the shell side Higher pressure fluid stream should be routed through the shell side The corrosive and fouling fluid should be preferably routed through the tubes Lower flow rate fluid should be routed through the shell side The viscous fluid should be routed through the shell side Higher pressure fluid stream should be routed through the shell side ANSWER DOWNLOAD EXAMIANS APP