A coil having large number of turns of fine wire is wound on the middle limb of the shunt magnet. This coil is known as pressure or voltage coil and is connected across the supply mains. The voltage coil produces a high ratio of inductance to resistance.
1.6 inches = 1.6 inches x 1,000 mils per inch = 1,600 mils 0.25 inch = 0.25 inch x 1,000 mils per inch = 250 mils Area = 1,600 x 250 = 400,000 square mils
A remote terminal unit (RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system and by using messages from the master supervisory. This is accomplished by transmitting telemetry data to the system and/or changing the physical state of connected objects based on control messages received from the automation system. It is used to interface field devices with SCADA. RTUs can support multiple communication protocols at the same time. A limited number of input and output devices can be added to it.
Frequency response analysis is the technique whereby a sinusoidal test signal is used to measure points on the frequency response of a transfer function or impedance function. Sweep Frequency Response Analysis (SFRA) testing provides insight into the mechanical and electrical integrity of transformers.
Main Purpose of SFRA Test: Transformer Core displacement Winding displacement for both rotor and transformer Broken or loosen clamp connections Inter turn short circuit Internal short circuit Winding to Core Earth fault Winding Open circuit condition
Voltage equation for Dc shunt generator, Eb = V + Ia*Ra V = Ish*Rsh Ish = 200/100 = 2 A Eb = V + Ia*Ra 20 = Ia*Ra Ia = 20/0.2 = 100 A I = 100 - 2 = 98 A