Electrical Machines
Consider the following statements about commutating poles which are fitted on most large dc Shunt motors: 1. The commutating poles are placed in the geometric neutral plane and their number is usually Equal to the number of main poles 2. The winding on the commutating poles is connected in series with the shunt-field winding on the main poles 3. The polarity of the commutating pole must be that of the next pole further ahead 4. The commutating poles neutralize the reactance voltage produced in the coil undergoing Commutation. Of these statements,

 1, 2 and 3 are correct
 1, 2 and 4 are correct
 2, 3 and 4 are correct
 1 and 4 are correct

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
Two synchronous generators operating in parallel 200 MW and 400 MW respectively. The drooping characteristics of their governors are 4% and 5% from no load to full load. Consider the governors operating at 50Hz on no load. How will the machine share, if the load is 600 MW?

 generator 2 gets over load
None of these
 generator 1 gets over load
 200 MW and 400MW