Electrical Machines Direct-on-line (DOL) starters are not suitable for starting large DC motors, because the motor may run away. the starting torque becomes low. the starting current will be enormously high. the motor may not start. the motor may run away. the starting torque becomes low. the starting current will be enormously high. the motor may not start. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In travelling cranes for swing action which motor is preferred? Capacitor type induction motors. Reluctance motor. DC series motor. AC slip ring IM. Capacitor type induction motors. Reluctance motor. DC series motor. AC slip ring IM. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines With the increase in speed of a DC motor back emf falls and line current increases. both back emf as well as line current increase. back emf increases but line current falls. both back emf as well as line current fall. back emf falls and line current increases. both back emf as well as line current increase. back emf increases but line current falls. both back emf as well as line current fall. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Two 3-phase AC generators are such that one has twice the linear dimensions of the other. The field windings of each are excited to give identical sinusoidal air-gap flux density waveform. Both have the same number of stator slots and identical winding patterns. The conductor/slot in a big generator is K times that of the smaller one. The value of K to get equal no load voltage at same frequency is 4. 1/2. 8. 1/4. 4. 1/2. 8. 1/4. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In synchronous generator, inverted V curve is drawn between field current on Y-axis and power factor on X-axis field current on Y-axis and armature current on X-axis field current on X-axis and armature current on Y-axis field current on X-axis and power factor on Y-axis field current on Y-axis and power factor on X-axis field current on Y-axis and armature current on X-axis field current on X-axis and armature current on Y-axis field current on X-axis and power factor on Y-axis ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Due to magnetic saturation, the flux per pole in a DC machine without brush shift increases in both the generators and the motors with load. decreases in generators and increases in motor with load. decreases in both generators and the motors with load. increases in generators but decreases in motor with load. increases in both the generators and the motors with load. decreases in generators and increases in motor with load. decreases in both generators and the motors with load. increases in generators but decreases in motor with load. ANSWER DOWNLOAD EXAMIANS APP