Process Equipment and Plant Design Corrosion allowance in the design of pressure vessel/chemical equipment is not necessary, if Both B & C Material of construction is high alloy steel Plain carbon steel and cast iron parts are used Wall thickness is > 30 mm Both B & C Material of construction is high alloy steel Plain carbon steel and cast iron parts are used Wall thickness is > 30 mm ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The ratio for the rate of washing to the final rate of filtration in a washing type of plate and frame filter is 0.75 1.25 0.5 0.25 0.75 1.25 0.5 0.25 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design 1.2 to 3.8 cms is the value of the All of these Static submergence in case of a bubble cap tray for column operating under pressure (≥ 1 atm.) Skirt clearance for bubble caps Downcomer liquid seal in case of a balanced tray design All of these Static submergence in case of a bubble cap tray for column operating under pressure (≥ 1 atm.) Skirt clearance for bubble caps Downcomer liquid seal in case of a balanced tray design ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design A forced circulation long tube vertical evaporator as compared to the natural circulation evaporator Employs high velocity, high heat transfer rate and less heating surface requirement Both B & C Employs a centrifugal pump placed between external downtake from vapor drum and inlet to tube bundle Is economical in operation Employs high velocity, high heat transfer rate and less heating surface requirement Both B & C Employs a centrifugal pump placed between external downtake from vapor drum and inlet to tube bundle Is economical in operation ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design For a 25 mm hole drilled in plates to be rivetted, the shank diameter of the rivet should be __________ mm. 26 27 23 25 26 27 23 25 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement about routing of fluids in a shell and tube heat exchanger. The corrosive and fouling fluid should be preferably routed through the tubes Lower flow rate fluid should be routed through the shell side The viscous fluid should be routed through the shell side Higher pressure fluid stream should be routed through the shell side The corrosive and fouling fluid should be preferably routed through the tubes Lower flow rate fluid should be routed through the shell side The viscous fluid should be routed through the shell side Higher pressure fluid stream should be routed through the shell side ANSWER DOWNLOAD EXAMIANS APP