Simple logic of reactance diagram is that simplified equivalent circuit of power system in which the various components of power system are represented by their reactance. The reactance diagram can be obtained from impedance diagram if all the resistive components are neglected. So, from figure each of the component is represented by its reactance.
Bus Type - Known Parameter - Unknown Parameter Load Bus -P, Q - V, phase angle Generator Bus - P, V (magnitude) - Q, Voltage phase angle Slack Bus Voltage - magnitude and phase angle - P, Q
Let, E→EMF in volt φ→Flux in weber A→Parallel path (for wave winding = 2) Z→No. of armature conductors N→speed in rpm P = Number of poles E = PφNZ/(60A) E = 8*0.020*625/(60*2) E = 500 V
Intern turn winding fault can be easily detect by differential protection relay. Also detect by buchholz relay (gas operated relay), cause buchholz relay is used to detect the internal fault of transformer.