Power Systems A loss less transmission line having surge impedance loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30 %. Then SIL of compensated transmission line will be 1835 MW. 2280 MW. 3257 MW. 2725 MW. 1835 MW. 2280 MW. 3257 MW. 2725 MW. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The term self GMD is used to calculate resistance inductance both 1 and 2 capacitance resistance inductance both 1 and 2 capacitance ANSWER DOWNLOAD EXAMIANS APP
Power Systems A network containing 50 buses in which 10 are the voltage control buses, 6 are the generator buses. Find the size of the Jacobian matrix? 84*84 34*34 33*33 83*83 84*84 34*34 33*33 83*83 ANSWER DOWNLOAD EXAMIANS APP
Power Systems Skin effect depends on frequency relative permeability All of these conductivity frequency relative permeability All of these conductivity ANSWER DOWNLOAD EXAMIANS APP
Power Systems The conductor carries more current on surface as compared to core. This is called as skin effect unsymmetrical fault All of these corona effect skin effect unsymmetrical fault All of these corona effect ANSWER DOWNLOAD EXAMIANS APP
Power Systems The Y bus matrix of 100 bus interconnected system is 90% sparse. Hence the number of transmission lines in the system must be 250 450 900 500 250 450 900 500 ANSWER DOWNLOAD EXAMIANS APP