MGVCL Exam Paper (30-07-2021 Shift 1)
A grid interactive solar system:

supplies power to as well as receives power from the grid as required
works only when the grid fails
always supplies power to the grid
always receives power from the grid

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 1)
Three equal star-connected inductors take 8 kW at 0.8 power factor when connected to a 460 V three - phase 3-wire supply. If one of the inductor in phase – Y is short circuited, then the line current in phase-Y is ___ Assume RYB sequence.

21.7 A
27.6 A
31.7 A
37.6 A

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 1)
A balanced delta connected load of 8+j6 Ω per phase is connected to a 415 V, 50 Hz, 3-phase supply lines. If the input power factor is improved to 0.9 by connecting a star connected capacitor bank, then the required kVAR of the bank is

10.98 kVAR
14.98 kVAR
16.98 kVAR
8.98 kVAR

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 1)
Consider the following statements and choose the correct option:
Statement 1: The magnitude of earth fault current for a given fault position within a winding depends upon the method of neutral grounding.
Statement 2: Earth fault protection for an electric motor is provided by means of instantaneous overcurrent relay.

Both Statement 1 and Statement 2 are FALSE
Statement 1 is FALSE and Statement 2 is TRUE
Both Statement 1 and Statement 2 are TRUE
Statement 1 is TRUE and Statement 2 is FALSE

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 1)
Voltage dips cannot be caused by which of the following:

Local and Remote faults
Switching on of Large Loads
Inductive Loading
Capacitive Switching

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP