Two-wattmeter method is used to measure the power taken by a 3-phase induction motor on no load. The wattmeter readings are 400 W and -50 W. Calculate the reactive power taken by the load
Symmetrical breaking current is the moment when fault occurs maximum fault current is observed and decays with respect to time. Symmetrical breaking current = RMS value of ac component of short circuit current at the instant of separation of the contacts. Symmetrical breaking capacity is less than asymmetrical breaking capacity.
A coil having large number of turns of fine wire is wound on the middle limb of the shunt magnet. This coil is known as pressure or voltage coil and is connected across the supply mains. The voltage coil produces a high ratio of inductance to resistance.
Bus Type - Known Parameter - Unknown Parameter Load Bus -P, Q - V, phase angle Generator Bus - P, V (magnitude) - Q, Voltage phase angle Slack Bus Voltage - magnitude and phase angle - P, Q