Process Equipment and Plant Design The difficulty of liquid distribution in packed towers is accentuated, when the ratio of tower diameter to packing diameter is > 7 < 15 < 30 > 20 < 50 < 7 > 7 < 15 < 30 > 20 < 50 < 7 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Overall mass transfer co-efficient in case of absorption of __________ in water is based on the gas film co-efficient only, as the mass transfer process is gas film (phase) controlling. None of these SO₂ NH₃ CO₂ None of these SO₂ NH₃ CO₂ ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The circumferential (hoop) stress in a thin walled cylinderical vessel under internal pressure is pd/3t pd/t pd/2t pd/4t pd/3t pd/t pd/2t pd/4t ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Generally, elliptical dished heads Are manufactured on 2:1 ratio of major to minor axis and is recommended to be used for pressure vessels operating above a pressure of 1.5 MN/m² Are approximately as strong as seamless cylindrical shell having the corresponding I.D and O.D All of these Resist half the pressure rating compared to hemi spherical head provided on the cylindrical shell of the same thickness and diameter Are manufactured on 2:1 ratio of major to minor axis and is recommended to be used for pressure vessels operating above a pressure of 1.5 MN/m² Are approximately as strong as seamless cylindrical shell having the corresponding I.D and O.D All of these Resist half the pressure rating compared to hemi spherical head provided on the cylindrical shell of the same thickness and diameter ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design For a cylinderical vessel of moderate height, the weld joint efficiency for joints parallel to the cylinderical axis is given as 1.0, while for joints along the girth (circumference) it is given as 0.8. In calculating the shell wall thickness using code formula for an internally pressurised cylinderical vessel, what value of weld joint efficiency should be used? 0.9 (0.8)0.5 1 0.8 0.9 (0.8)0.5 1 0.8 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Shell side heat transfer co-efficient in case of square pitch as compared to the triangular pitch under similar condition of fluid flow and tube size is Twice Less More Same Twice Less More Same ANSWER DOWNLOAD EXAMIANS APP