Building Construction Rotary drilling Is not economical for holes of less than 10 cm All listed here Hinders the ground water observations and permeability test Is not suitable for deposits containing very coarse gravel Is not economical for holes of less than 10 cm All listed here Hinders the ground water observations and permeability test Is not suitable for deposits containing very coarse gravel ANSWER DOWNLOAD EXAMIANS APP
Building Construction To ensure that supporting area of an offset footing of a boundary wall is fully compressive, the C.G. of load must act Within the middle fifth of the base At the centre of the base Neither (A), (B) nor (C) Within the middle third of the base Within the middle fifth of the base At the centre of the base Neither (A), (B) nor (C) Within the middle third of the base ANSWER DOWNLOAD EXAMIANS APP
Building Construction Auger boring All of these Is most economical up-to a depth of 5 meters Is generally employed in cohesive and other self soils above water table Is the most primitive method for making a hole in the ground All of these Is most economical up-to a depth of 5 meters Is generally employed in cohesive and other self soils above water table Is the most primitive method for making a hole in the ground ANSWER DOWNLOAD EXAMIANS APP
Building Construction The skirting/dado in a bath roof should be upto Level of the tap Ceiling 200 cm 15 cm above floor level Level of the tap Ceiling 200 cm 15 cm above floor level ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Distance of G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m Area of footing slab = 11.00 m2 All listed here Distance of G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m Area of footing slab = 11.00 m2 All listed here ANSWER DOWNLOAD EXAMIANS APP
Building Construction Pick up the consideration to the taken while designing a hospital from the following: The operation theater unit to be detached as it requires sterilized zone but near the ward for the patients and doctor Casualty unit should be provided a separate entrance The mortuary should be detached from the main circulation with a post-mortem room All listed here The operation theater unit to be detached as it requires sterilized zone but near the ward for the patients and doctor Casualty unit should be provided a separate entrance The mortuary should be detached from the main circulation with a post-mortem room All listed here ANSWER DOWNLOAD EXAMIANS APP