DGVCL Exam Paper (11-12-2011) Reactance relay is used to protect against Earth faults only Both phase and earth faults Over voltage faults Phase faults only Earth faults only Both phase and earth faults Over voltage faults Phase faults only ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) DC series motors are best suited for traction work because Its torque is proportional to the square of the armature current and speed is directional proporational to torque Torque and speed are proportional to the square of the armature current Its torque is proportional to the square of the armature current and speed is inversely proportional to torque Torque and speed are inversely proportional to the square of the armature current Its torque is proportional to the square of the armature current and speed is directional proporational to torque Torque and speed are proportional to the square of the armature current Its torque is proportional to the square of the armature current and speed is inversely proportional to torque Torque and speed are inversely proportional to the square of the armature current ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Torque in d.c motor = k* φ * IaIn series motor φ α IaTα I²N α 1/φN α 1/T
DGVCL Exam Paper (11-12-2011) The picture on the monitor of a computer is made up of tiny coloured dots called Icons Spots Points Pixels Icons Spots Points Pixels ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Under operating conditions, the secondary of a current transformer is always short ciruited because It is safe to human beings It protects the secondary ciruits It protects the primary ciruits It avoids core saturation and high voltage induction It is safe to human beings It protects the secondary ciruits It protects the primary ciruits It avoids core saturation and high voltage induction ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) In the protection of transformers, harmonic restraint is used to guard against Unbalanced protection Switching over voltages Magnetizing inrush current Lightning Unbalanced protection Switching over voltages Magnetizing inrush current Lightning ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Initial inrush of magnetizing currents have high component of even and odd harmonics.2nd - 63%3rd -26.8%4th- 5.1%5th- 4.1%6th- 3.77th-2.4
DGVCL Exam Paper (11-12-2011) It is difficult interrupt a capacitive current because It has a leading power factor The restriking voltage can be high Current magnitude is very small Stored energy in the capacitor is very high It has a leading power factor The restriking voltage can be high Current magnitude is very small Stored energy in the capacitor is very high ANSWER DOWNLOAD EXAMIANS APP