Building Construction Pile foundations are suitable for Multi-storeyed buildings Compact soils Soft rocks Water logged soils Multi-storeyed buildings Compact soils Soft rocks Water logged soils ANSWER DOWNLOAD EXAMIANS APP
Building Construction The type of ashlar masonry in which stones are finely chisel dressed and thickness of joints does not exceed 3 mm, is Chamfered ashlar masonry Coursed ashlar masonry Ashlar facing masonry Random coursed ashlar masonry Chamfered ashlar masonry Coursed ashlar masonry Ashlar facing masonry Random coursed ashlar masonry ANSWER DOWNLOAD EXAMIANS APP
Building Construction Pick up the correct statement about silt soil from the following: In organic fine grained silt soil possesses no plasticity All listed here The silt soil has particle size from 0.02 mm to 0.06 mm The least plastic type normally consists of more or less equidimensional grains of quartz In organic fine grained silt soil possesses no plasticity All listed here The silt soil has particle size from 0.02 mm to 0.06 mm The least plastic type normally consists of more or less equidimensional grains of quartz ANSWER DOWNLOAD EXAMIANS APP
Building Construction You are asked to design and supervise a truss for a factory to have spans 6 m to 9 m. The type of the truss you will use, is King post truss Collar truss Mansard truss Queen post truss King post truss Collar truss Mansard truss Queen post truss ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: All listed here Area of footing slab = 11.00 m2 Distance of C.G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m All listed here Area of footing slab = 11.00 m2 Distance of C.G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m ANSWER DOWNLOAD EXAMIANS APP
Building Construction Brick nogging type of partition wall, is constructed by Laying bricks as headers in cement mortar Laying bricks as stretchers in cement mortar Constructing brick work within a wooden framework Reinforcing brick wall with iron straps Laying bricks as headers in cement mortar Laying bricks as stretchers in cement mortar Constructing brick work within a wooden framework Reinforcing brick wall with iron straps ANSWER DOWNLOAD EXAMIANS APP