Measurement and Instrumentation The resistance of a circuit is measured from the relation R= P/I2, where P is the power fed into the circuit and I is the current flowing through it. If the limiting errors in the measurement of power and current are respectively ± 1.0% and ± 1.0%, then what will be the limiting error in measurement of resistance ? ±3.5% ± 1.5% ±0.5% ± 3.0% ±3.5% ± 1.5% ±0.5% ± 3.0% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation Assertion (A) : Precision is a necessary prerequisiteof accuracy. Reason (R) : Precision guarantees accuracy. Both A and R are true but R is NOT the correct explanation of A Both A and R are true and R is the correct explanation of A A is true but R is false A is false bur R is true Both A and R are true but R is NOT the correct explanation of A Both A and R are true and R is the correct explanation of A A is true but R is false A is false bur R is true ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation An ammeter of range 0-25 A has a guaranteed accuracy of 1% of full-scale reading. The current measured by the ammeter is 5 A. The limiting error in the reading is 3% 4% 6% 5% 3% 4% 6% 5% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation In a wheatstone bridge, a change of 6 Ω in the unknown arm of bridge is required to produce a change in deflection of 2.4 mm of the galvanometer. The sensitivity is 5.0 mm/Ω 2.5 mm/Ω 0.8 mm/Ω 0.4 mm/Ω 5.0 mm/Ω 2.5 mm/Ω 0.8 mm/Ω 0.4 mm/Ω ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation For a circuit given that I = 2 ± 5 % A, R = 100 ± 0.2 % Ω the limiting error in the power dissipation I2 R in the resistor R is 1.2% 10.2% 25.2% 5.2% 1.2% 10.2% 25.2% 5.2% ANSWER DOWNLOAD EXAMIANS APP