Measurement and Instrumentation An ammeter of range 0-25 A has a guaranteed accuracy of 1% of full-scale reading. The current measured by the ammeter is 5 A. The limiting error in the reading is 3% 5% 4% 6% 3% 5% 4% 6% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation An average reading digital multimeter reads 10 V when fed a triangular wave, symmetric about the axis. For the same input, an rms reading meter will read 20. 20√3. 10√3. 10. 20. 20√3. 10√3. 10. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation For a circuit given that I = 2 ± 5 % A, R = 100 ± 0.2 % Ω the limiting error in the power dissipation I2 R in the resistor R is 5.2% 1.2% 25.2% 10.2% 5.2% 1.2% 25.2% 10.2% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation Schering bridge is used to measure which of the following? Frequency. Capacitance. Inductance. Resistance. Frequency. Capacitance. Inductance. Resistance. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation If two meters X and Y require 40 mA and 50 mA respectively, to give full scale deflection, then X is more sensitive. Both X and Y are equally sensitive. It would not be possible to assess the sensitivity on the basis of the given data. Y is more sensitive. X is more sensitive. Both X and Y are equally sensitive. It would not be possible to assess the sensitivity on the basis of the given data. Y is more sensitive. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation Consider the following statement - 1. The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil. 2. The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the voltage coil circuit. 1 is true but 2 is false. Both 1 and 2 are false. Both 1 and 2 are true. 1 is false but 2 is true. 1 is true but 2 is false. Both 1 and 2 are false. Both 1 and 2 are true. 1 is false but 2 is true. ANSWER DOWNLOAD EXAMIANS APP