Process Equipment and Plant Design
In case of design of a shell and tube heat exchanger,

Minimum cleaning lane of 6.5 mm is provided, when tubes are on a square pitch
All of these
Minimum tube sheet thickness (in which tubes are fixed) is equal to the O.D. of the tube upto 15 mm tube diameter; and for > 15 mm tube diameter, tube sheet thickness is smaller than tube diameter
O.D. of the tube is 6 to 40 mm while the tube lengths used are 0.5, 2.5, 3.0, 4.0, 5.0, 6 metres

ANSWER DOWNLOAD EXAMIANS APP

Process Equipment and Plant Design
Weep holes provided in the plates of a distillation column

Must be large enough (usually 1/4" to 5/8" dia) to prevent plugging but should not deliver excessive amount of fluid during operation
Are normally located near the overflow weir so that any delivery of liquid during operation follows approximately the same path as the overflow fluid
All of these
Facilitate draining out liquid from a tray when the unit is not in operation

ANSWER DOWNLOAD EXAMIANS APP