Electrical Machines In salient pole synchronous machine, if direct axis reactance and quadrature axis reactance is equal, then power developed due to reluctance is zero maximum infinite value any of the above zero maximum infinite value any of the above ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In case of 3 - Φ IM, plugging means interchanging two supply phases for quick stopping. locking of rotor due to harmonics. starting the motor on load which is more than the rated load. pulling the motor directly on line without a rotor. interchanging two supply phases for quick stopping. locking of rotor due to harmonics. starting the motor on load which is more than the rated load. pulling the motor directly on line without a rotor. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In an alternator, voltage drops occurs in armature resistance, leakage reactance, armature reaction and earth connection. armature resistance only. armature resistance, leakage reactance and armature reaction. armature resistance and leakage reactance. armature resistance, leakage reactance, armature reaction and earth connection. armature resistance only. armature resistance, leakage reactance and armature reaction. armature resistance and leakage reactance. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Consider the following statements: To control the speed of a dc shunt motor above the base speed over a reasonably wide range, the motor must 1. have compensating winding 2. have interpole winding 3. be started using a 3-point starter 4. be started using a 4-point starter Of these statements 1, 2 and 3 are correct 2 and 4 are correct 1, 2 and 4 are correct 1 and 3 are correct 1, 2 and 3 are correct 2 and 4 are correct 1, 2 and 4 are correct 1 and 3 are correct ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Synchronous reactance of an alternator represents All of these armature reactance and leakage reactance a reactance operating at synchronous speed field winding reactance All of these armature reactance and leakage reactance a reactance operating at synchronous speed field winding reactance ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The fall in speed of the DC generator due to increase in load can be corrected by cooling the armature. increasing the excitation. reducing the load voltage. increasing the input to the prime mover. cooling the armature. increasing the excitation. reducing the load voltage. increasing the input to the prime mover. ANSWER DOWNLOAD EXAMIANS APP