Power Systems In case of failure of prime mover of the generator, which type of relay is used? offset mho relay distance relays impedance relay reverse power relay offset mho relay distance relays impedance relay reverse power relay ANSWER DOWNLOAD EXAMIANS APP
Power Systems If the time of operation of a relay for unity TMS is 10 sec. the time of operation of 0.5 TMS will be _______________ secs. 7. 3. 20. 5. 7. 3. 20. 5. ANSWER DOWNLOAD EXAMIANS APP
Power Systems Which of the following is/are the advantages of synchronous phase modifier over the shunt compensation? both 1 and 2 single unit can be used as both capacitance and inductor by adjusting the excitation initial cost is low smooth voltage regulation is possible by controlling excitation both 1 and 2 single unit can be used as both capacitance and inductor by adjusting the excitation initial cost is low smooth voltage regulation is possible by controlling excitation ANSWER DOWNLOAD EXAMIANS APP
Power Systems The VSWR of transmission line is Proportional to load and characteristic impedance. Directly proportional to load impedance and inversely to characteristic impedance. Directly proportional to characteristic impedance and inversely to load impedance. Directly proportional to voltage minimum and inversely proportional to voltage maximum. Proportional to load and characteristic impedance. Directly proportional to load impedance and inversely to characteristic impedance. Directly proportional to characteristic impedance and inversely to load impedance. Directly proportional to voltage minimum and inversely proportional to voltage maximum. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The arc voltage produced in an AC circuit breaker is always lagging the arc current by 90°. in phase opposition with the arc current. leading the arc current by 90°. in phase with the arc current. lagging the arc current by 90°. in phase opposition with the arc current. leading the arc current by 90°. in phase with the arc current. ANSWER DOWNLOAD EXAMIANS APP
Power Systems Which of the following statements is/are true? The elements of each row of a Y bus matrix for load flow studies in power system add up to zero always if the shunt admittances at the buses are ignored if both 2 and 3 are satisfied if the mutual couplings between transmission lines are absent always if the shunt admittances at the buses are ignored if both 2 and 3 are satisfied if the mutual couplings between transmission lines are absent ANSWER DOWNLOAD EXAMIANS APP