Process Equipment and Plant Design In a multipass shell and tube heat exchanger, the problem of differential expansion between the shell and tube passes is taken care of by using a U-bend Either A or B Neither A nor B Floating head tube sheet U-bend Either A or B Neither A nor B Floating head tube sheet ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Number of evaporators which can be used in service in a multiple effect evaporation system is limited by the Neither A nor B Both A & B Practical limit reached, due to low heat transfer rate because of inadequate temperature difference Economic limit reached, when the plant cost exceeds the saving of steam Neither A nor B Both A & B Practical limit reached, due to low heat transfer rate because of inadequate temperature difference Economic limit reached, when the plant cost exceeds the saving of steam ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Le/D for fully open globe value may be around 10 300 25 75 10 300 25 75 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Normally, the plate thickness of the bottoms and roofs of vertically cylindrical storage vessels as compared to that of the cylindrical shell is Less More Same More or less depending upon the pressure & temperature inside the vessel and the nature of the fluid contained therein Less More Same More or less depending upon the pressure & temperature inside the vessel and the nature of the fluid contained therein ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement pertaining to the design of the distillation column. The purpose of the slot is to disperse the gas into the liquid in the form of small bubbles Generally, a skirt clerance of 0.5" to 1.5' is recommended to prevent plugging of the slots by residue build up None of these If sufficient slot area is not provided, the gas may pass through the skirt clearance The purpose of the slot is to disperse the gas into the liquid in the form of small bubbles Generally, a skirt clerance of 0.5" to 1.5' is recommended to prevent plugging of the slots by residue build up None of these If sufficient slot area is not provided, the gas may pass through the skirt clearance ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design A binary liquid azeotropic mixture has boiling point lower than either of the components, when it shows __________ deviation from Raoult's Law. No Positive None of these Negative No Positive None of these Negative ANSWER DOWNLOAD EXAMIANS APP