DGVCL Exam Paper (11-12-2011) If the voltage at the two ends of a line are 132 kV, and its reactance is 40 Ω, the stability limit of the line is 500 MW 217.8 MW 251.5 MW 435.6 MW 500 MW 217.8 MW 251.5 MW 435.6 MW ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) The main criterion for the design of a distributor is Corona loss Temperature rise Voltage drop Radio interference Corona loss Temperature rise Voltage drop Radio interference ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) The purpose of interpoles in DC machines is to nullify The cross-magnetizing effect of armature mmf The demagnetizing effect of armature mmf The reactance voltage Both the cross-magnetizing mmf and the reactance voltage The cross-magnetizing effect of armature mmf The demagnetizing effect of armature mmf The reactance voltage Both the cross-magnetizing mmf and the reactance voltage ANSWER EXPLANATION DOWNLOAD EXAMIANS APP interpoles is widely use to improve commutationplace between main poles fitted to yokefunctions:to neutralize armature mmf in commutating zoneto produce some flux in commutating zone
DGVCL Exam Paper (11-12-2011) An IDMT relay provides A definite time cuttent characteristic An inverse time current characteristic A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current A definite time cuttent characteristic An inverse time current characteristic A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) In the protection of transformers, harmonic restraint is used to guard against Switching over voltages Lightning Magnetizing inrush current Unbalanced protection Switching over voltages Lightning Magnetizing inrush current Unbalanced protection ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Initial inrush of magnetizing currents have high component of even and odd harmonics.2nd - 63%3rd -26.8%4th- 5.1%5th- 4.1%6th- 3.77th-2.4
DGVCL Exam Paper (11-12-2011) If a relay fails to operate inspite of a fault in its own zone of protection, it is said to Over reach Reach Under reach Pick up Over reach Reach Under reach Pick up ANSWER DOWNLOAD EXAMIANS APP