Concrete Technology and Design of Concrete Structures If the size of panel in a flat slab is 6m x 6m, then as per Indian Standard Code, the widths of column strip and middle strip are 3.0 m and 1.5 m 3.0 m and 3.0 m 1.5 m and 1.5 m 1.5 m and 3.0 m 3.0 m and 1.5 m 3.0 m and 3.0 m 1.5 m and 1.5 m 1.5 m and 3.0 m ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures In prestressed concrete both forces of tension and compres-sion as well as lever arm change forces of tension and compression change but lever arm remains unchanged both forces of tension and compres-sion as well as lever arm remain unchanged forces of tension and compressions remain unchanged but lever arm changes with the moment both forces of tension and compres-sion as well as lever arm change forces of tension and compression change but lever arm remains unchanged both forces of tension and compres-sion as well as lever arm remain unchanged forces of tension and compressions remain unchanged but lever arm changes with the moment ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures In a ring beam subjected to uniformly distributed loadi) shear force at mid span is zeroii) shear force at mid span is maximumiii) torsion at mid span is zeroiv) torsion at mid span is maximum The correct answer is (ii) and (iii) (i) and (iv) (ii) and (iv) (i) and (iii) (ii) and (iii) (i) and (iv) (ii) and (iv) (i) and (iii) ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures According to IS : 456- 1978, minimum slenderness ratio for a short column is more than 24 less than 18 between 18 and 24 less than 12 more than 24 less than 18 between 18 and 24 less than 12 ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Assertion A : The load factor for live load is greater than that for dead load.Reason R : The live loads are more uncertain than dead loads.Select your answer based on the coding system given below : Both A and R are true and R is the correct explanation of A. Both A and R are true but R is not the correct explanation of A. A is true but R is false. A is false but R is true. Both A and R are true and R is the correct explanation of A. Both A and R are true but R is not the correct explanation of A. A is true but R is false. A is false but R is true. ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures The depth of footing for an isolated column is governed byi) maximum bending momentii) shear forceiii) punching shearThe correct answer is (i) and (iii) only (i) (i), (ii) and (iii) (i) and (ii) (i) and (iii) only (i) (i), (ii) and (iii) (i) and (ii) ANSWER DOWNLOAD EXAMIANS APP