Power Systems For symmetrical network, the neutral current is any of the above zero infinity maximum any of the above zero infinity maximum ANSWER DOWNLOAD EXAMIANS APP
Power Systems The surge impedance of a 400 km long overhead transmission line is 420 Ω. For a 200 km length of the same line, the surge impedance will be 400 Ω 840 Ω 420 Ω 210 Ω 400 Ω 840 Ω 420 Ω 210 Ω ANSWER DOWNLOAD EXAMIANS APP
Power Systems The sequence components of the fault current are as follows : Ipositive = j1.5 pu, Inegative = − j0.5 pu, Izero = − j pu Which fault is this? LG. LLG. LL. LLLG. LG. LLG. LL. LLLG. ANSWER DOWNLOAD EXAMIANS APP
Power Systems In a short circuit test circuit breaker, time to reach the peak re-striking voltage 60 microsecond & the peak re-striking voltage 120 kV. Determine average RRRV (Rate of rise re-striking voltage)? 2 × 106 kV / sec. 3.5 × 106 kV / sec. 1 × 106 kV / sec. 3 × 106 kV / sec. 2 × 106 kV / sec. 3.5 × 106 kV / sec. 1 × 106 kV / sec. 3 × 106 kV / sec. ANSWER DOWNLOAD EXAMIANS APP
Power Systems Gas turbine power plants for maximum efficient may have Reheating. Multistage compression. Heat exchangers. All of above. Reheating. Multistage compression. Heat exchangers. All of above. ANSWER DOWNLOAD EXAMIANS APP
Power Systems Consider a long, two wire line composed of solid round conductors. The radius of both conductors is 0.25 cm and distance between their centers is 100 cm. If this distance is doubled, then the inductance per unit length. Decrease but does not halves. Doubled. Increase but does not doubled. Halves. Decrease but does not halves. Doubled. Increase but does not doubled. Halves. ANSWER DOWNLOAD EXAMIANS APP