Refrigeration and Air Conditioning Condensing temperature in a refrigerator is the temperature Of cooling medium Of evaporator Of freezing zone At which refrigerant gas becomes liquid Of cooling medium Of evaporator Of freezing zone At which refrigerant gas becomes liquid ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The coefficient of performance of Electrolux refrigerator is the ratio of Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator to the heat supplied by the gas burner ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In order to cool and dehumidify a stream of moist air, it must be passed over the coil at a temperature Which lies between the wet bulb and dew point temperatures of the incoming stream Which is lower than the dew point temperature of the incoming stream Of adiabatic saturation of incoming stream Which lies between the dry bulb and wet bulb temperatures of the incoming stream Which lies between the wet bulb and dew point temperatures of the incoming stream Which is lower than the dew point temperature of the incoming stream Of adiabatic saturation of incoming stream Which lies between the dry bulb and wet bulb temperatures of the incoming stream ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The operating temperature of a cold storage is -2°C. The heat leakage from the surrounding is 30 kW for the ambient temperature of 40°C. The actual C.O.P. of refrigeration plant used is one fourth that of ideal plant working between the same temperatures. The power required to drive the plant is 7.44 kW 1.86 kW 3.72 kW 18.6 kW 7.44 kW 1.86 kW 3.72 kW 18.6 kW ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The suction pipe diameter of refrigerating unit compressor in comparison to delivery side is Equal Smaller Smaller/bigger depending on capacity Bigger Equal Smaller Smaller/bigger depending on capacity Bigger ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The specific humidity during dehumidification process Remains constant Decreases Increases None of these Remains constant Decreases Increases None of these ANSWER DOWNLOAD EXAMIANS APP