A single phase full converter bridge, connected to 230 V, 50 Hz source is feeding a load R =10 Ω in series with a large inductance that makes the load current ripple free. For a firing angle of 450, calculate the rectification efficiency.
Dynamic voltage restoration (DVR) is a method of overcoming voltage sags and swells that occur in electrical power distribution. Devices used for DVR include static var devices, which are series compensation devices that use voltage source converters (VSC). The DVR is used to inject three phase voltage in series and in synchronism with the network voltages in order to compensate voltage disturbances with a benefit of active /reactive power control.
The tendency of a Reach of Distance Relay to operate at impedance larger than its setting value is known as overreach. Overreach is the presence of d.c. offset in the fault current wave, as the offset current has a higher peak value than that of a symmetrical wave for which the relay is set.
1.6 inches = 1.6 inches x 1,000 mils per inch = 1,600 mils 0.25 inch = 0.25 inch x 1,000 mils per inch = 250 mils Area = 1,600 x 250 = 400,000 square mils