Process Equipment and Plant Design A single pass air heater is connected to a two pass unit. For the air flow rate and other conditions remaining the same, the film heat transfer co-efficient for air will vary in the ratio of 2 20.8 20.2 None of these 2 20.8 20.2 None of these ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The wall thickness for a large high pressure pipeline is determined by the consideration of the Axial tensile stress in the pipe Circumferential pipewall tension Temperature stresses Forces exerted by static and dynamic action at bends Axial tensile stress in the pipe Circumferential pipewall tension Temperature stresses Forces exerted by static and dynamic action at bends ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Movement of pipeline caused by thermal expansion is taken care by providing Expansion joint Change in the shape of pipeline All of these Changes in its direction Expansion joint Change in the shape of pipeline All of these Changes in its direction ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design An increase in the liquid resistance to interphase mass transfer and a resultant reduction in plate efficiency is caused by All of these An increase in relatived volatility for rectification columns Decrease in gas solubility for absorbers An increase in liquid viscosity All of these An increase in relatived volatility for rectification columns Decrease in gas solubility for absorbers An increase in liquid viscosity ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Weep holes provided in the plates of a distillation column Facilitate draining out liquid from a tray when the unit is not in operation All of these Must be large enough (usually 1/4" to 5/8" dia) to prevent plugging but should not deliver excessive amount of fluid during operation Are normally located near the overflow weir so that any delivery of liquid during operation follows approximately the same path as the overflow fluid Facilitate draining out liquid from a tray when the unit is not in operation All of these Must be large enough (usually 1/4" to 5/8" dia) to prevent plugging but should not deliver excessive amount of fluid during operation Are normally located near the overflow weir so that any delivery of liquid during operation follows approximately the same path as the overflow fluid ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design In condenser, the cooling water is passed in the tube side in a pass arrangement, because It makes condenser compact It reduces heat transfer area Pressure drop is reduced More thinner tubes can be used It makes condenser compact It reduces heat transfer area Pressure drop is reduced More thinner tubes can be used ANSWER DOWNLOAD EXAMIANS APP