Electrical Machines A self-excited shunt generator fails to build up, because 1. the field circuit is open 2. The armature circuit is open 3. the residual magnetism is absent 4. The direction of rotation is wrong From these, the correct answer is 1, 3 3 only 1, 2, 3 and 4 1, 2 and 3 1, 3 3 only 1, 2, 3 and 4 1, 2 and 3 ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The compensating winding in a DC machine is located on commutating poles for improving commutation. is located on pole shoes to avoid the sparking at the brushes. is located on pole shoes for avoiding the flashover at the commutator. is located in armature slots for compensation of the armature reaction. is located on commutating poles for improving commutation. is located on pole shoes to avoid the sparking at the brushes. is located on pole shoes for avoiding the flashover at the commutator. is located in armature slots for compensation of the armature reaction. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Which of the following statements are correct ? Both 1 and 2. A small value of leakage reactance will increase the maximum power output of motor. The leakage reactance of the induction motor should be small. None of these Both 1 and 2. A small value of leakage reactance will increase the maximum power output of motor. The leakage reactance of the induction motor should be small. None of these ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Quadrature axis synchronous reactance is the ratio of Vmin to Imin. Vmin to Imax. Vmax to Imin. Vmax to Imax. Vmin to Imin. Vmin to Imax. Vmax to Imin. Vmax to Imax. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Two synchronous generators operating in parallel 200 MW and 400 MW respectively. The drooping characteristics of their governors are identical as 4% from no load to full load. Consider the governors operating at 50Hz on no load. How will the machine share, if the load is 600 MW? generator 1 gets over load generator 2 gets over load 230.7 MW and 369.23 MW respectively 200 MW and 400MW respectively generator 1 gets over load generator 2 gets over load 230.7 MW and 369.23 MW respectively 200 MW and 400MW respectively ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A short-shunt cumulatively-compounded dc generator builds up a voltage of 220 V at no load at rated speed. If it is operated as a differentially compounded generator, other things remaining the same, it would build up 220 V 6 V more than 220 V somewhat less than 220 V 220 V 6 V more than 220 V somewhat less than 220 V ANSWER DOWNLOAD EXAMIANS APP