Measurement and Instrumentation A potentiometer may be used for All of the listed here Calibration of ammeter Measurrment of resistance Measurement of current All of the listed here Calibration of ammeter Measurrment of resistance Measurement of current ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A current of is measured with a thermocouple, 5 A full scale meter. What is the meter reading? 6.09 A. 4.06 A. 5 A. 2.03 A. 6.09 A. 4.06 A. 5 A. 2.03 A. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The material of the shunt should have _______ temperature co-efficient of resistance. Positive Negligible None of the listed here Negative Positive Negligible None of the listed here Negative ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A voltage of 2.70 V is being measured by an analog indicating instrument having a scale range of 0 – 5.0 V. If the instrument reads 2.65 V, then absolute error in measurement is 0.01V 0.05V 0.01V 0.25V 0.01V 0.05V 0.01V 0.25V ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100°hm. This is to have full deflection when 100V is measured. What is the value of series resistor to be used? 100 K ohms 99.99 K ohms 99.99 ohms 100 ohms 100 K ohms 99.99 K ohms 99.99 ohms 100 ohms ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A 50 Hz bar primary CT has a secondary with 500 turns. The secondary supplies 5 A current into a purely resistive burden of 1Ω. The magnetizing ampere-turn is 200. The phase angle between the primary and secondary current is 4.6o. 85.4o. 94.6o. 175.4o. 4.6o. 85.4o. 94.6o. 175.4o. ANSWER DOWNLOAD EXAMIANS APP