Measurement and Instrumentation In a dynamometer wattmeter, the moving coil is the Current coil Current coil and potential coil None of the listed here Potential coil Current coil Current coil and potential coil None of the listed here Potential coil ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A voltage of 2.70 V is being measured by an analog indicating instrument having a scale range of 0 – 5.0 V. If the instrument reads 2.65 V, then absolute error in measurement is 0.05V 0.25V 0.01V 0.01V 0.05V 0.25V 0.01V 0.01V ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A sampling wattmeter is used to measure the average power of a load. The peak to peak voltage of a square wave is 10 V and the current is triangular wave of 5 Amp P-P as shown in the figure. The period is 20 ms. The reading in W will be 50 W. 100 W. 25 W. 0 W. 50 W. 100 W. 25 W. 0 W. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation In flux meter, the controlling torque is produced by spring. not provided at all. crossed coil mechanism. weight attached to the moving coil. spring. not provided at all. crossed coil mechanism. weight attached to the moving coil. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation For a circuit given that I = 2 ± 5 % A, R = 100 ± 0.2 % Ω the limiting error in the power dissipation I2 R in the resistor R is 1.2% 5.2% 25.2% 10.2% 1.2% 5.2% 25.2% 10.2% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A thermo couple ammeter gives full scale deflection of 10 A, when it reads one fifth of the scale, the current will be 4.47 A. 2 A. 5.78 A. 4 A. 4.47 A. 2 A. 5.78 A. 4 A. ANSWER DOWNLOAD EXAMIANS APP