Electrical Machines
When a short circuit test on a transformer is performed at 25 V, 50 Hz, the drawn current is I1. If the test is performed by 25 V and 25 Hz and power drawn current is I2, then

 I1 = I2
None of these
 I1 > I2
 I1 < I2

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
Two synchronous generators operating in parallel 200 MW and 400 MW respectively. The drooping characteristics of their governors are 4% and 5% from no load to full load. Consider the governors operating at 50Hz on no load. How will the machine share, if the load is 600 MW?

 200 MW and 400MW
None of these
 generator 1 gets over load
 generator 2 gets over load

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
The results of a slip test for determining direct axis (Xd) and quadrature axis (Xq) reactances of a star connected salient pole alternator are given below Phase values: Vmax = 108 V ; Vmin = 96 V Imax = 12 A ; Imin = 10 A Hence the two reactances will be

 Xd = 8Ω and Xq = 10.8Ω
 Xd = 10.8Ω and Xq = 8Ω
 Xd = 9Ω and Xq = 9.6Ω
 Xd = 9.6Ω and Xq = 9Ω

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
Compensating windings are used in DC generators

  to provide path for the circulation of cooling air.
None of these
  to neutralize the cross magnetizing effect of the armature reaction.
  mainly to reduce the eddy currents by providing local short circuit.