Electrical Machines
Two transformers with identical rating, are designed with flux densities of 1.2 and 1.4 Wb / m2 respectively. The weight of first transformer per kVA is

  more than that of second transformer.
 none of these.
 less than that of second transformer.
 equal to that of second transformer.

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
The result of slip test on a 3-phase, 20 KVA, 400 V, 50 Hz connected salient pole alternator is given below- Phase value: Vmax = 100 V, Vmin = 96 V, Imax = 10 A and I min = 7 A. The direct and quadranature axis reactances are respectively

 8.248 and 5.54 Ω.
  14.28 and 5.54 Ω.
 14.28 and 9.60 Ω.
 8.248 and 9.60 Ω.

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
Compensating windings are used in DC generators

  to neutralize the cross magnetizing effect of the armature reaction.
  mainly to reduce the eddy currents by providing local short circuit.
  to provide path for the circulation of cooling air.
None of these

ANSWER DOWNLOAD EXAMIANS APP