Building Construction
Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following:

All listed here
The length of the foundation slab = 7.00 m
Area of footing slab = 11.00 m2
Distance of C.G. of the loads from the smaller column = 3.00 m

ANSWER DOWNLOAD EXAMIANS APP

Building Construction
Pick up the consideration to the taken while designing a hospital from the following:

The operation theater unit to be detached as it requires sterilized zone but near the ward for the patients and doctor
All listed here
The mortuary should be detached from the main circulation with a post-mortem room
Casualty unit should be provided a separate entrance

ANSWER DOWNLOAD EXAMIANS APP