Building Construction For the construction of flyovers in sandy soils, the type of foundation provided, is Combined footing Raft footing Strap footing Pier footing Combined footing Raft footing Strap footing Pier footing ANSWER DOWNLOAD EXAMIANS APP
Building Construction Herringbone bond is used for All of these Walls having thickness more than 4 bricks Ornamental panels in brick flooring Architectural finish to the face work All of these Walls having thickness more than 4 bricks Ornamental panels in brick flooring Architectural finish to the face work ANSWER DOWNLOAD EXAMIANS APP
Building Construction Black cotton soil is unsuitable for foundations because its Permeability is uncertain Bearing capacity is low Particles are cohesive Property to undergo a volumetric change due to variation of moisture content Permeability is uncertain Bearing capacity is low Particles are cohesive Property to undergo a volumetric change due to variation of moisture content ANSWER DOWNLOAD EXAMIANS APP
Building Construction The piece of a brick cut with its one corner equivalent to half the length and half the width of a full brick, is known as Half king closer King closer Bevelled closer Queen closer Half king closer King closer Bevelled closer Queen closer ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Area of footing slab = 11.00 m2 All listed here G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m Distance of Area of footing slab = 11.00 m2 All listed here G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m Distance of ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m Distance of C.G. of the loads from the smaller column = 3.00 m All listed here Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m Distance of C.G. of the loads from the smaller column = 3.00 m All listed here ANSWER DOWNLOAD EXAMIANS APP