Building Construction The window which projects outside a room of a building for admitting more light and air, is known Lantern window Casement window Dormer window Bay window Lantern window Casement window Dormer window Bay window ANSWER DOWNLOAD EXAMIANS APP
Building Construction A wall constructed to resist the pressure of an earth filling, is called Breast wall Parapet wall Buttress Retaining wall Breast wall Parapet wall Buttress Retaining wall ANSWER DOWNLOAD EXAMIANS APP
Building Construction Pick up the correct specification of one-room quarters generally adopted from the following: The front verandah is kept 2 m wide All listed here The size of room is either 3.5 m × 3 m or 4.2 m × 2.5 m Six quarters in a row The front verandah is kept 2 m wide All listed here The size of room is either 3.5 m × 3 m or 4.2 m × 2.5 m Six quarters in a row ANSWER DOWNLOAD EXAMIANS APP
Building Construction The additional piles which are driven to increase the capacity of supporting loads on vertical piles, are known Sinking piles Construction piles Raking piles Eccentric piles Sinking piles Construction piles Raking piles Eccentric piles ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Distance of Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m All listed here G. of the loads from the smaller column = 3.00 m Distance of Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m All listed here G. of the loads from the smaller column = 3.00 m ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Distance of C.G. of the loads from the smaller column = 3.00 m Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m All listed here Distance of C.G. of the loads from the smaller column = 3.00 m Area of footing slab = 11.00 m2 The length of the foundation slab = 7.00 m All listed here ANSWER DOWNLOAD EXAMIANS APP