Power Systems The positive, negative and zero sequence impedances of a transmission line are 0.5,0.5 and 1.1 pu respectively. The self (Zs) and mutual (Zm) impedances of the line will be given by Zs = 0.6 pu, Zm =0.5 pu Zs = 0.5 pu, Zm =0.6 pu Zs = 0.7 pu, Zm =0.2 pu Zs = 0.2 pu, Zm =0.7 pu Zs = 0.6 pu, Zm =0.5 pu Zs = 0.5 pu, Zm =0.6 pu Zs = 0.7 pu, Zm =0.2 pu Zs = 0.2 pu, Zm =0.7 pu ANSWER DOWNLOAD EXAMIANS APP
Power Systems India 1st nuclear plant was set up at Kalpakkam. Bhaba. Rana pratap sagar. Tarapur. Kalpakkam. Bhaba. Rana pratap sagar. Tarapur. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The load duration curve for a system is 8 hours 30 MW, 16 hours 25 MW and 24 hours 20 MW. The load factor will be 0.44. 1.3. 0.83. 0.25. 0.44. 1.3. 0.83. 0.25. ANSWER DOWNLOAD EXAMIANS APP
Power Systems Apart from the skin effect the non uniformity of the current distribution is also caused by proximity effect All of these bundled conductors ferranti effect proximity effect All of these bundled conductors ferranti effect ANSWER DOWNLOAD EXAMIANS APP
Power Systems The unit protection scheme provides primary protection. simultaneous protection. back up protection. remote protection. primary protection. simultaneous protection. back up protection. remote protection. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The capacitance of an overhead transmission line increases with both 1 and 2 increase in mutual geometrical mean distance increase in height of conductors above ground neither 1 nor 2 both 1 and 2 increase in mutual geometrical mean distance increase in height of conductors above ground neither 1 nor 2 ANSWER DOWNLOAD EXAMIANS APP