Refrigeration and Air Conditioning The bypass factor for a cooling coil Remains unchanged with increase in velocity of air passing through it Decreases with increase in velocity of air passing through it May increase or decrease with increase in velocity of air passing through it depending upon the condition of air entering Increases with increase in velocity of air passing through it Remains unchanged with increase in velocity of air passing through it Decreases with increase in velocity of air passing through it May increase or decrease with increase in velocity of air passing through it depending upon the condition of air entering Increases with increase in velocity of air passing through it ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The conditioned air supplied to the room must have the capacity to take up Both room sensible heat and latent heat loads None of the listed here Room latent heat load only Room sensible heat load only Both room sensible heat and latent heat loads None of the listed here Room latent heat load only Room sensible heat load only ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A thermostatic expansion valve in a refrigeration system None of these Maintains different temperatures in evaporator in proportion to load Is suitable only for constant load systems Ensures the evaporator completely filled with refrigerant of the load None of these Maintains different temperatures in evaporator in proportion to load Is suitable only for constant load systems Ensures the evaporator completely filled with refrigerant of the load ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The optimum effective temperature for human comfort is Higher in winter than in summer Same in winter and summer Not dependent on season Lower in winter than in summer Higher in winter than in summer Same in winter and summer Not dependent on season Lower in winter than in summer ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning As relative humidity decreases, the dew point temperature will be ___ wet bulb temperature. Same as None of the listed here Higher than Lower than Same as None of the listed here Higher than Lower than ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The sensible heat factor during the heating and humidification process is given by (where h₁ = Enthalpy of air entering the heating coil, h₂ = Enthalpy of air leaving the heating coil, and hA = Enthalpy of air at the end of humidification process) (h2 - hA)/ (h1 - h2) (hA - h2)/ (h1 - h2) (hA - h1)/ (h2 - h1) (h1 - h2)/ (hA - h2) (h2 - hA)/ (h1 - h2) (hA - h2)/ (h1 - h2) (hA - h1)/ (h2 - h1) (h1 - h2)/ (hA - h2) ANSWER DOWNLOAD EXAMIANS APP