Refrigeration and Air Conditioning A good refrigerant should have High latent heat of vaporisation and low freezing point Low C.O.P. and low freezing point High specific volume and high latent heat of vaporisation High operating pressures and low freezing point High latent heat of vaporisation and low freezing point Low C.O.P. and low freezing point High specific volume and high latent heat of vaporisation High operating pressures and low freezing point ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning One of the purposes of sub cooling the liquid refrigerant is to Ensure that only liquid and not the vapour enters the expansion (throttling) valve Reduce compressor overheating Reduce compressor discharge temperature Increase cooling effect Ensure that only liquid and not the vapour enters the expansion (throttling) valve Reduce compressor overheating Reduce compressor discharge temperature Increase cooling effect ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Moisture should be removed from refrigerants to avoid Freezing at the expansion valve All of these Restriction to refrigerant flow Corrosion of steel plates Freezing at the expansion valve All of these Restriction to refrigerant flow Corrosion of steel plates ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The wet bulb temperature at 100% relative humidity is___ dry bulb temperature. Higher than Same as None of the listed here Lower than Higher than Same as None of the listed here Lower than ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The bypass factor (B. P. F.) in case of sensible heating of air is (Where td₁ = Dry bulb temperature of air entering the heating coil, td₂ = Dry bulb temperature of air leaving the heating coil, and td₃ = Dry bulb temperature of heating coil) (td₂ - td₃)/(td₃ - td₁) (td₃ - td₁)/(td₃ - td₂) (td₃ - td₁)/(td₂ - td₃) (td₃ - td₂)/(td₃ - td₁) (td₂ - td₃)/(td₃ - td₁) (td₃ - td₁)/(td₃ - td₂) (td₃ - td₁)/(td₂ - td₃) (td₃ - td₂)/(td₃ - td₁) ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In a bootstrap air evaporative cooling system, the evaporator is provided Between the secondary compressor and the second heat exchanger Between the first heat exchanger and the secondary compressor Between the second heat exchanger and the cooling turbine Between the combustion chamber and the first heat exchanger Between the secondary compressor and the second heat exchanger Between the first heat exchanger and the secondary compressor Between the second heat exchanger and the cooling turbine Between the combustion chamber and the first heat exchanger ANSWER DOWNLOAD EXAMIANS APP