Measurement and Instrumentation Ryall crest voltmeter is used for measurement of AC voltage of any form High DC voltage Low frequency voltage High AC voltage AC voltage of any form High DC voltage Low frequency voltage High AC voltage ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The power factor of a single phase load can be calculated if the instruments available are One voltmeter and one ammeter One voltmeter, one ammeter and one wattmeter One ammeter, one voltmeter and one energy meter Any of the listed here One voltmeter and one ammeter One voltmeter, one ammeter and one wattmeter One ammeter, one voltmeter and one energy meter Any of the listed here ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging Pressure coil of the wattmeter will become ineffective. Both give the same readings One of the wattmeters will read zero One of the wattmeter connections will have to be reversed Pressure coil of the wattmeter will become ineffective. Both give the same readings One of the wattmeters will read zero One of the wattmeter connections will have to be reversed ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A 50 Hz bar primary CT has a secondary with 500 turns. The secondary supplies 5 A current into a purely resistive burden of 1Ω. The magnetizing ampere-turn is 200. The phase angle between the primary and secondary current is 4.6o. 175.4o. 94.6o. 85.4o. 4.6o. 175.4o. 94.6o. 85.4o. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation If two meters X and Y require 40 mA and 50 mA respectively, to give full scale deflection, then X is more sensitive. Both X and Y are equally sensitive. It would not be possible to assess the sensitivity on the basis of the given data. Y is more sensitive. X is more sensitive. Both X and Y are equally sensitive. It would not be possible to assess the sensitivity on the basis of the given data. Y is more sensitive. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A CRO probe has an impedance of 500 kΩ in parallel with a capacitance of 10 pF. The probe is used to measure the voltage between P and Q as shown in figure. The measured voltage will be 4.38 V. 3.53 V. 4.54 V. 5 V. 4.38 V. 3.53 V. 4.54 V. 5 V. ANSWER DOWNLOAD EXAMIANS APP